Referenced documents purchase separately the documents listed below are referenced within the subject standard but are not provided as part of the standard.
Drywall control joint standards.
093 zinc control joint is typically installed from door header to ceiling from floor to ceiling in.
C11 terminology relating to gypsum and related building materials and systems.
Control joints does not exceed 900 sq ft 84 m section 20 3 6 ga 4 7 3 6 a control joint or intermediate blocking shall be installed where ceiling framing members change direction section 20 3 7 ga 4 7 3 7 control joints shall be installed where specified by the architect or designer as a design accent or architectural feature.
C475 c475m specification for joint compound and joint tape for finishing gypsum board.
Offering lightweight construction the sheetrock ultralight 1 2 in.
With perimeter relief the maximum recommended control joint spacing is 50 feet.
A control joint shall be installed where a partition wall or ceiling traverses a.
Complete guide to proper joint treatment and surface preparation for drywall construction.
Drywall control joints referred to in some products and literature with the misnomer drywall expansion joints are used prevent cracking in gypsum wallboard.
Chapter 5 finishing drywall systems.
Perforations and ridges on all surfaces that receive finishing compound or veneer assure excellent adhesion.
Hand and mechanical finishing with setting type and drying type compounds.
In this 24 x 27 foot building area no drywall control joints were required.
Includes installation of corner beads trim and control joints.
Control joints does not exceed 2500 sq ft 230 m o section 20 3 4 ga 4 7 3 4 control joints in interior ceilings without perimeter relief shall be installed so that linear dimensions between control joints do not exceed 30 ft 9100 mm and total area between control joints does not exceed 900 sq ft 84 m.
Drywall for easier lifting carrying and installation.
Addresses special environmental and lighting situations.
Gypsum board is icc certified for sag resistance and eliminates the need for separate wall and ceiling panels.
Provides a 1 16 ground.
C514 specification for nails for the application of.
Amico drywall control joint deep v with removable tape is designed to help relieve stress in large areas of drywall or veneer plaster installations.
The longest un broken section of drywall was less than 27 feet in its longest dimension.
It weighs up to 30 less than traditional 1 2 in.
The maximum recommended control joint spacing for walls and ceilings without perimeter relief is 30 feet.
Offering lightweight construction the sheetrock ultralight 1 2 in.