Machine room doors shall be labeled elevator machine room with letters not less than two 2 inches 51 mm high.
Elevator machine room sign requirements.
Building the rooms to code means following the proper asme.
8 amend subdivision c of rule 101 5 to read as follows.
Location of machine rooms and control rooms.
By the elevator or in the hoistway or in an elevator machine room or a control space or a control room see 2 27 3 2 shall initiate phase i emergency recall operation.
For machine rooms and control rooms with double swing doors the doors shall swing out and the switch es shall be located on the wall adjacent to the hinge side of the active door panel.
2 elevator machine room control room and control space access doors shall be provided with a sign that reads elevator equipment room authorized personnel.
Elevator machine room sign 12x12 rust free heavy aluminum uv protected long lasting weather fade resistant easy mounting indoor outdoor use made in usa.
Elevator safety is a critical consideration for builders who have state safety codes to follow permits to obtain and regular inspections to pass.
4 elevator machine rooms or enclosed areas shall be kept free of all materials except those used for repair or maintenance of the elevator.
Passage to enclosed equipment installed within the elevator machine room to provide the ventilation required by section 3011 f 2 a.
Machine rooms shall be kept reasonably clean.
In traction elevator machine rooms install a beam above the elevator machine and motor that is sufficient in size and capacity to support the removal of elevator equipment.
Control switch shall be located on the lock jamb side of the access door.
Elevator machine room authorized personnel only sign 14x10 inch aluminum for elevator escalator by compliancesigns.
Size and configure the elevator machine room so that there is a minimum clearance of 18 between any building component and a traction elevator drive machine.
A permanent sign shall be mounted on the head jamb of the main floor elevator entrance which shall read mrl control room located on floor with the applicable floor.
Machine rooms and machinery space.
After the last sentence add.
Provide a fused disconnect switch for each elevator in the control room located in a position based on local code and within sight of elevator equipment and arranged to be locked in the off position.
7 amend subdivision a of rule 101 5 to read as follows.
Control room must be of adequate size to provide clearances around and between equipment as required by code.
Location of machinery spaces machine rooms control spaces control rooms and equipment 2 7 6 1.
The american society of mechanical engineers publishes the construction standards for elevator equipment rooms.
2 27 3 1 5 all fire recall switches shall be pro vided with an illuminated visual signal to indicate when phase i emergency recall operation is in effect.